logo
Brans Measuring And Controlling Technology Co., Ltd
prodotti
prodotti
Casa > prodotti > Cella di carico a singolo punto > Why the WL-116 Single Point Load Cell Solves Your Weighing Challenges Wide Capacity Range: 5kg–200kg | C3/C4 Accuracy | Parallel Ready

Why the WL-116 Single Point Load Cell Solves Your Weighing Challenges Wide Capacity Range: 5kg–200kg | C3/C4 Accuracy | Parallel Ready

Dettagli del prodotto

Luogo di origine: Cina

Marca: BRANS

Numero di modello: WL-116

Documento: WL-116 Single Point Load Ce...NS.pdf

Termini di trasporto & di pagamento

Quantità di ordine minimo: 1 pz

Imballaggi particolari: Imballaggio standard in cartone per esportatori, comprese le istruzioni.

Tempi di consegna: 5-7 giorni lavorativi

Termini di pagamento: L/C,T/T,Western Union,Paypal

Ottenga il migliore prezzo
Evidenziare:
Tipo:
Cella di carico di uscita analogica
Capacità di carico:
5 kg/10 kg/20 kg/30 kg/50 kg/100 kg/200 kg
Dimensioni del cavo:
Φ5,4×4000mm
Errore combinato:
± 0,01% F.S.
Dimensione massima della piattaforma:
600 mm × 500 mm
Sovraccarico sicuro:
150%F.S.
Sovraccarico ultimo:
300% F.S.
Personalizzabile:
Personalizzabile
Temp. Operation Temp.:
-30 ~ 70 ° C.
Tipo:
Cella di carico di uscita analogica
Capacità di carico:
5 kg/10 kg/20 kg/30 kg/50 kg/100 kg/200 kg
Dimensioni del cavo:
Φ5,4×4000mm
Errore combinato:
± 0,01% F.S.
Dimensione massima della piattaforma:
600 mm × 500 mm
Sovraccarico sicuro:
150%F.S.
Sovraccarico ultimo:
300% F.S.
Personalizzabile:
Personalizzabile
Temp. Operation Temp.:
-30 ~ 70 ° C.
Why the WL-116 Single Point Load Cell Solves Your Weighing Challenges Wide Capacity Range: 5kg–200kg | C3/C4 Accuracy | Parallel Ready

Why the WL-116 Single Point Load Cell Solves Your Weighing Challenges Wide Capacity Range: 5kg–200kg | C3/C4 Accuracy | Parallel Ready


Product Description:

Struggling to find a single point load cell that balances capacity with precision? The WL-116 single point load cell offers a solution, covering everything from 5kg light-duty scales to 200kg industrial platforms—all with C3/C4 accuracy.

Off-center loading errors are a common headache in weighing systems. The WL-116 single point load cell addresses this with a optimized structure that minimizes sensitivity to uneven weight distribution, ensuring that this single point load cell delivers accurate readings regardless of load position.

Need to build a larger platform? No problem. The WL-116 single point load cell is engineered for output uniformity, meaning multiple units of this single point load cell can be connected in parallel without complex calibration routines. Each single point load cell in the series shares the same electrical and mechanical characteristics.

For automated production lines, the WL-116 single point load cell offers the speed and stability required for dynamic weighing. Whether integrated into a checkweigher or a filling system, this single point load cell responds quickly and maintains accuracy over millions of cycles.

From agriculture to chemical processing, the WL-116 single point load cell has proven its worth in harsh environments. If you need a single point load cell that delivers precision, consistency, and long-term reliability, the WL-116 is the answer.

Specifications:



Capacity 5kg/10kg/ 20kg/ 30kg/ 50kg/ 100kg/200kg
Rated output

2.0±10%mV/V

Accuracy class C3/C4
Combined error ±0.01%F.S. 
Zero balance ±0.2%mV/V
Non-linearity ±0.017%F.S.
Hysteresis ±0.017%F.S.
Repeatability ±0.01%F.S.
Creep (30min) ±0.017%F.S.
Temperature effect on sensitivity ±0.017%F.S./10℃
Temperature effect on zero ±0.02%F.S./10℃
Input resistance 420±20Ω
Output resistance 350±10Ω
Insulation resistance ≥5000MΩ/100VDC
Recommended excitation 5-15VDC
Compensated temp. range -10~40℃
Operation temp. range -10~50℃
Safe overload 150%F.S.
Ultimate overload 300%F.S.
IP class IP68 (Customizable)
Cable size Φ5.2×4000mm (Customizable)
Material Aluminum alloy
Max.platform size 600mm×500mm






Dimension(MM):

     

           Why the WL-116 Single Point Load Cell Solves Your Weighing Challenges Wide Capacity Range: 5kg–200kg | C3/C4 Accuracy | Parallel Ready 0                    


                                       


Load Direction:

Why the WL-116 Single Point Load Cell Solves Your Weighing Challenges Wide Capacity Range: 5kg–200kg | C3/C4 Accuracy | Parallel Ready 1
 

Wiring:

Why the WL-116 Single Point Load Cell Solves Your Weighing Challenges Wide Capacity Range: 5kg–200kg | C3/C4 Accuracy | Parallel Ready 2

Why the WL-116 Single Point Load Cell Solves Your Weighing Challenges Wide Capacity Range: 5kg–200kg | C3/C4 Accuracy | Parallel Ready 3

Why the WL-116 Single Point Load Cell Solves Your Weighing Challenges Wide Capacity Range: 5kg–200kg | C3/C4 Accuracy | Parallel Ready 4

Load Cell Packaging and Shipping


To ensure safe arrival at your location, the load cell will be carefully packaged and shipped. The packing process is as follows:

1. The load cell will be placed in a sturdy cardboard box to protect it from external damage during shipping.
2. The box will be filled with foam padding to provide additional cushioning and prevent the load cell from moving during shipping.
3. The load cell will be sealed in a plastic bag to protect it from moisture and other environmental factors.
4.  Additional layers of bubble wrap will be provided for additional protection.
5. The carton is securely taped to prevent tampering.
6. A shipping label with your address and product information is attached to the box.
7. The package is shipped using a reliable and trusted freight carrier.


Once the package is shipped, you will receive a tracking number to monitor the status of your delivery. Please ensure that someone is available at the delivery address to receive the package to avoid any delays or problems.